Kalibrasi Multimeter
Kalibrasi Multimeter
Multimeter Calibrator
The equipment 0.05 unmarried-phase AC/DC standard source, tin verify magnitude 0.2 and the following Air-conditioning/DC voltmeter, ammeter, frequency meter, resistance meter.
The source signals by using DSP and xvi-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.
The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system.
Information technology has precise interface and multi-functions including verification, storage and query.
Features
-
It can be semi-automac or transmission inspecon of analog mul meter, clench type electric current meter, all kinds of electrical meter, (voltmeter, ammeter, frequency meters, resistance meter) basic error.
- The equipment can be generated with 2-31 harmonic wave, harmonic number, order, amplitude and harmonic stage of fundamental wave tin can be programmed.
- Power amplifier working frequency range is 40Hz-1KHZ, has a good linear. Current amplifier is abiding current source; voltage amplifier is constant voltage source. Because of light weight, this device is more suitable for field use.
- With RS-232 interface, this device is controlled by PC through the PC and thenware (oponal), can be automac or manual inspecon, and the results are processing and management
- Has a non-volale retentiveness, information technology can store 500 pieces of the raw data of tested meter, for access and upload.
Specification
Ability supply
Single stage AC 220V±10% 50/60HzAC
AC Voltage output
Range 200mV, 400mV, 2000mV, 4000mV,
20V, 100V, 200V, 500V, 1000V
Range 20V-1000V Accuracy ±(0.3%RD+0.2%FS)
Stability ≤0.04% FS /60s
Ac Current Output
Range 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A
Range 0.2A-20A Accuracy ±(0.03%RD+0.02%FS)
Stability ≤0.01% FS /60s
Range 2mA-40mA Accuracy ±(0.3%RD+0.2%FS)
Stability ≤0.04% FS /60s
Frequency Output Range 45-65Hz Fineness 0.001Hz Accurateness 0.01Hz
DC voltage output Range 200mV, 400mV, 2000mV, 4000mV,
20V, 40V, 100V, 200V, 400V, 1000V
Stability ≤0.01% FS /60s (peak-peak value)
Accuracy ±(0.03%RD+0.02%FS)
DC current output
Range 20uA, 40uA, 200uA, 400uA, 2mA, 4mA,
20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A
Stability ≤0.01% FS /60s (elevation-elevation value)
Accuracy ±(0.06%RD+0.04%FS)
Resistance
Range 0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-4kΩ, 0-20kΩ, 20kΩ-40kΩ,
0-200kΩ, 200kΩ-400kΩ, 0-2MΩ, 2MΩ-4MΩ
Range 0-2kΩ, 0-20kΩ, 0-200kΩ
Range 0-2kΩ accuracy ±(0.12%RD+0.08%FS)
Range 0-200Ω,0-2MΩ accuracy ±(0.3%RD+0.two%FS)
Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ
Range 2kΩ-4kΩ accuracy ±(0.12%RD+0.08%FS)
Range 200-400Ω, 2MΩ-4MΩ accuracy ±(0.3%RD+0.ii%FS)
Clamp meter range
200A Accurateness ±0.2%
600A Accurateness ±0.5%
chiliad Accuracy ±1%